MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
RTCTMR_FLAGS.overflow_flag_a
Field
Bits
Default
Access
Description
overflow_flag_a
11
0 (RTC POR only)
R/O
RTC Overflow 4kHz Flag
Original event detection flag from 4kHz domain.
RTCTMR_FLAGS.trim_flag_a
Field
Bits
Default
Access
Description
trim_flag_a
12
0 (RTC POR only)
R/O
RTC Trim Event 4kHz Flag
Original event detection flag from 4kHz domain.
RTCTMR_FLAGS.async_clr_flags
Field
Bits
Default
Access
Description
async_clr_flags
31
0
W/O
Asynchronous RTC Flag Clear
Writing a 1 to this bit triggers a one-shot operation which clears the RTC Compare 0/1 flags, the RTC Prescale Compare flag, the RTC Overflow flag, and the RTC
Trim Event flag both in this register and in the 4kHz clock domain.
This bit always reads 0.
10.3.5.1.7
RTCTMR_INTEN
RTCTMR_INTEN.comp0
Field
Bits
Default
Access
Description
comp0
0
0
R/W
RTC Time of Day Alarm (Compare 0) Interrupt Enable
Rev.1.3 April 2015
Maxim Integrated
Page 577