Flow-X─ Function Reference
4-309
Flow-X General functions - fxVCone_C
Density
Exponent.
This factor is used when density correction is
enabled. The formula 1/
will be used when
the input value is set to 0, else the input
value will be used.
For more details refer to section 'Density
correction'.
-
0
Fluid
The type of fluid being measured
1: Gas
2: Liquid
-
1
Discharge
coefficient
The McCrometer reference document states
that the discharge coefficient is a function of
Reynolds number. A calibration correction
needs to be implemented through an
additional function and input 'Discharge
coefficient' needs to be linked to the
corresponding output of this additional
function.
-
0..2
0.85
Function outputs
Remark
EU
Fallback
Status
0: Normal (No error condition)
1: Input argument out of range
2: No convergence
Mass flow rate
The calculated mass flow rate
klbm/hr
0
Beta ratio
Cone to pipe diameter ratio at upstream
temperature
-
Input Cone
diameter /
Input Pipe
diameter
Cone diameter
At the upstream temperature
inches
Input Cone
diameter
Pipe diameter
At the upstream temperature
inches
Input Pipe
diameter
Upstream pressure
Pressure at upstream tapping (p
1
)
psia
Input
Pressure
Pressure at
downstream
tapping
Pressure at downstream tapping (p
2
)
psia
Input
Pressure
Recovered
downstream
pressure
Fully recovered downstream pressure (p
3
)
psia
Input
Pressure
Upstream
temperature
Temperature at upstream tapping (t
1
)
°F
Input
Temperature
Temperature at
downstream
tapping
Temperature at downstream tapping (t
2
)
°F
Input
Temperature
Downstream
Temperature
'Fully recovered' downstream temperature (t
3
)
°F
Input
Temperature
Upstream density
Density at upstream tapping (
1
)
lbm/ft3
Input Density
Density at
downstream
tapping
Pressure at downstream tapping (
2
)
lbm/ft3
Input Density
Downstream
density
'Fully recovered' downstream density (
3
)
lbm/ft3
Input Density
Reynolds number
-
0
Discharge
coefficient
Same as input value
-
Expansion Factor
-
0
Velocity
Pipeline velocity
Ft/s
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...