4-88
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Dens20C_NGL_LPG
Function outputs
Name
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of
range
Outputs will be set to
fallback values
2: Calculation error
Outputs will be set to
fallback values
3: No convergence within 15
iterations
Outputs will be set to
values of last iteration
-
STS
FIOOR
CALC
NOCONV
1
Output density
Depending on the conversion
method this represents the
density either at 20
°
C and
the equilibrium pressure or
the observed temperature
and pressure
kg/m3
DENS
0
CTL
Volume correction factor for
temperature.
Value will be rounded
according to input 'API 11.2.4
rounding'
-
CTL
1
CPL
Volume correction factor for
pressure
Value will be rounded
according to input 'API
11.2.2M rounding'
-
CPL
1
CTPL
Combined volume correction
factor
CTPL = CTL * CPL
-
CTPL
1
F
Compressibility factor
The output value will be
either rounded or not
depending input 'API
rounding'
1/bar
F
0
Equilibrium
pressure
The equilibrium pressure
calculated by GPA TP-15
Will be set to 0 when
equilibrium pressure is below
atmospheric pressure
bar(a)
EQUIPCUR
0
CTL calc out of
range
With respect to the API
11.2.4 standard the
combination of input values
is:
0: In Range
1: Out of Range
The following range checks
apply:
Conversion method 1:
observed -> standard
0.21 <= RD <= 0.74
with RD = Input
CTLOOR
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...