352 Fault tracing
1 Slip frequency is too small
Check the settings of the motor
configuration parameters in groups 98
and 99.
Check that the drive is sized correctly for
the motor.
2 Synchronous and nominal
speeds differ too much
3 Nominal speed is higher than
synchronous speed with 1 pole
pair
4 Nominal current is outside
limits
5 Nominal voltage is outside
limits
6 Nominal power is higher than
apparent power
7 Nominal power not consistent
with nominal speed and torque
A6A5
No motor data
Parameters in group 99 have
not been set.
Check that all the required parameters in
group 99 have been set.
Note:
It is normal for this warning to
appear during the start-up and continue
until the motor data is entered.
A6A6
Supply voltage
unselected
The supply voltage has not
been defined.
Set supply voltage in parameter
A6B0
User lock is open
The user lock is open, ie. user
lock configuration parameters
…
Close the user lock by entering an invalid
pass code in parameter
).
A6B1
User pass code not
confirmed
A new user pass code has
been entered in parameter
but not confirmed in
.
Confirm the new pass code by entering
the same code in
. To cancel,
close the user lock without confirming the
new code. See section
(page
).
A6D1
FBA A parameter
conflict
The drive does not have a
functionality requested by a
PLC, or requested functionality
has not been activated.
Check PLC programming.
Check settings of parameter groups
and
A6DA Reference source
parametrization
A reference source is
simultaneously connected to
multiple parameters with
different units.
Check the reference source selection
parameters.
Check the auxiliary code (format
XXYY 00ZZ). “XX” and “YY” specify the
two sets of parameters where the source
was connected to (
01
= speed reference
chain [
,
,
02
=
frequency reference chain [
],
03
= torque reference chain [
04
= other torque-related
parameters [
],
“ZZ” indicates the conflicting reference
source (
01…0E
= index in parameter
group 3,
3D
= motor potentiometer,
65
=
AI1,
66
= AI2,
6F
= frequency input).
Code
(hex)
Warning
Cause
What to do
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...