WARNING!
If jogging is enabled and activated while the start command is on,
jogging will activate as soon as the start command switches off.
• If both jogging functions are activated, the one that was activated first has priority.
• Jogging uses the speed control mode.
• Ramp shape times (parameters
) do not apply to jogging
acceleration/deceleration ramps.
• The inching functions activated through fieldbus (see
bits 8…9) use the references and ramp times defined for jogging, but do not
require the jog enable signal.
Settings
(page
(page
) and
Scalar motor control
It is possible to select scalar control as the motor control method instead of vector
control. In scalar control mode, the drive is controlled with a speed or frequency
reference. However, the outstanding performance of vector control is not achieved in
scalar control.
It is recommended to activate scalar motor control mode
• if the nominal current of the motor is less than 1/6 of the nominal output current of
the drive
• if the drive is used without a motor connected (for example, for test purposes)
• if the drive runs a medium-voltage motor through a step-up transformer, or
• in multimotor drives, if
•
the load is not equally shared between the motors,
•
the motors are of different sizes, or
•
the motors are going to be changed after motor identification (ID run)
In scalar control, some standard features are not available.
See also section
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...