9.4.1 Inputs to iVu (Outputs from PLC)
PLC Assembly Instance 112 (0x70) - 6 Registers (iVu Inputs/PLC Outputs)
Data transfer direction: Originator (PLC) to Target (iVu Plus). Assembly Instance 112 (0x70) is a small group of registers
used for basic control of the iVu Plus.
WORD #
WORD NAME
DATA TYPE
0
Input Bits Register (see
Input and Output Flags Bits
on page 115)
16-bit integer
1-2
Product Change Number
32-bit integer
3-5
reserved
16-bit integer
PLC Assembly Instance 113 (0x71) - 240 Registers (iVu Inputs/PLC Outputs)
Data transfer direction: Originator (PLC) to Target (iVu Plus). Assembly Instance 113 (0x71) has more registers than
Assembly Instance 112. This allows for more comprehensive control of the iVu Plus, including Command Channel
functionality.
WORD #
WORD NAME
DATA TYPE
0
Inputs Bit Register (see
Input and Output Flags Bits
on page 115
16-bit integer
1-2
Product Change Number
32-bit integer
3-49
reserved
32-bit integer
50
Command ID
16-bit integer
51
Command Parameter Int16
16-bit integer
52-53
Command Parameter Int32
32-bit integer
54-55
Command Parameter Float
Float
56-57
String Length
32-bit integer
58-107
String Parameter
100 Byte Array
108
reserved
16-bit integer
109-110
Barcode String/Mask Length
32-bit integer
111-210
Barcode String/Mask
200 Byte Array
211-239
reserved
16-bit integer
9.4.2 Outputs from the iVu (Inputs to the PLC)
PLC Assembly Instance 100 (0x64) - 30 Registers (iVu Outputs/PLC Inputs)
Data transfer direction: Target (iVu Plus) to Originator (PLC). Assembly Instance 100 is a small block of registers providing
basic inspection results from the iVu Plus.
NOTE: Assembly Instance 100 does not provide sensor-specific information.
WORD #
WORD NAME
DATA TYPE
0
Input Bits ACK Register (see
Input and Output Flags Bits
on page 115)
16-bit integer
1
Output Bits Register (see
Input and Output Flags Bits
on page 115)
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
iVu Plus TG Gen2 Image Sensor