XG700 User's Guide
118/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
5.9.5 flowcontorol
Function
Sets transmission and reception modes for the PAUSE frame for Flow Control to the switch port. Additionally, Flow Control by
receiving the PAUSE frame is always enabled.
Use the no form to return to the default setup.
Prompt
xg(config-if)#, or xg(config-agg)#
Command syntax
flowcontorol { only-receive | send-receive }
no flowcontorol
Parameter
only-receive
Enables reception of Flow Control by the PAUSE frame to switch ports.
send-receive
Enables Flow Control by transmission and reception of the PAUSE frame to switch ports. If this is set, PAUSE frame is
transmitted when the frame transmission buffer space runs out.
Command type
Configuration command
Default
only-receive
Message
% The Setting of flowcontrol cannot be done to send-receive %1$
Explanation
Since the setting of jumbo-frame is 15360, "send-receive" cannot be set.
[[Inserted string]]%1$: port name
Solution
Check the setting of jumbo-frame, change it to other than 15368, and execute the command again.
Example
Enable flow control by sending and receiving PAUSE frame.
xg(config-if)# flowcontorol send-receive