E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 26
Data 2 = ’Z’
Data 3 = ’K’
Two strings can be returned: the default value – ‘AZK’ and a string whose value is
programmed in the Factory (maximum 10 characters)
Command protected by a PIN.
Notes:
a)
If the Exit module does not have their tables correctly programmed the default value
(“AZK”) is returned. If it is correctly programmed the value programmed in Factory is
returned.
5.9
REQUEST EQUIPMENT CATEGORY ID [245]
This command permits the reception of a string of characters from the Validator that identifies
the type of device it is: ‘Coin Validator’
Send:
[Dir] [0] [1] [245] [Chk]
Reply:
[1] [13] [Dir] [0] [‘C’] [‘o’] [‘i’] [‘n’] [‘ ’] [‘A’] [‘c’] [‘c’] [‘e’] [‘p’] [‘t’] [‘o’]
[‘r’] [Chk] -> ACK with 13 data
Where:
Dir = address of the corresponding validator
Command protected by a PIN.
5.10
REQUEST PRODUCT CODE [244]
With this command, the Validator returns the code of product of the device to the Machine.
The complete identification of the product can be determined using the command REQUEST
PRODUCT CODE followed by the command REQUEST BUILD CODE [192].
Send:
[Dir] [0] [1] [244] [Chk]
Reply:
[1] [n] [Dir] [0] [Data 1] ... [Data n] [Chk] -> ACK with n data
Where:
Dir = address of the corresponding validator