E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 83
-
Data 32 – 45: String of 14 chars:
-
“00000000-0,v00” if something of the following occurs: The Sensor module has its
firmware incomplete or it does not respond, the Exit module has its firmware
incomplete, the Validator is not or bad programmed or the data configuration are not
valid. In anyone of these cases the Validator can not admit any coin.
-
“332XXXXX-X,vXX” if the Sensor and Exit modules do not have a compatible coin
programming. This string corresponds to the coin programming reference of the Exit
module. In this case the Validator could work although with a reduced performance.
The error code returned can be 6 or 7 (see Table 11).
-
“41XXXXXX-X,vXX” if the coin programming in both modules are correct an
coincident. The Validator is working normally.
-
Data 46: Module number connected. If the Sensor module has responded, the value
returned is 2. If the Sensor module has not, it responds with the value 1.
-
Data 47: Firmware version of the Sensor module. It is a binary value from 1 to 255. In
case of error the value can be one of the following:
-
0: The Sensor module does not respond
-
255: The firmware of the Sensor module is incomplete.
-
Data 48: Firmware version of the Exit module. It is a binary value from 1 to 255.
-
Data 49 and 50: Reserved for future use.
-
Data 51: Error code resulting from the comparison of the programming coin
characteristics between the Sensor and Exit modules. See Table 11.
Table 11: Command “Request Modules Information”: error codes
Code Description
0 No
errors
1
Sensor Module not connected or it is not working
2
Incorrect firmware of the Exit Module
3
Incorrect firmware of the Sensor Module
4
Validator (Sensor Module or Exit Module) with incorrect
programming or not programmed.