E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 31
Where:
Dir = address of the corresponding validator
Data 1 = Values
Bit 0 – Bit 3: always at 0 (is equivalent to closed switches)
Bit 4: String detector mechanism (0 = closed / 1 = open)
The X6 validator does not have any switches, thus it returns always 0: closed switches
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded.
b)
The X6 validator does not answer to this command if it is not programmed in “L66
compatibility” mode.
5.16
READ OPTO STATES [236]
Using this command, the Validator returns a byte which indicates the value of the optic sensors
in the validator: Photo transistors detecting Coin Exit and String detector.
Send:
[Dir] [0] [1] [236] [Chk]
Reply:
[1] [1] [Dir] [0] [Data 1] [Chk] -> ACK with a data
Where:
Dir = address of the corresponding validator
Data 1 = Values
Bit 0: Not used = 0
Bit 1: 0 if all of the measurement fototransistors of the Sensor Module are
free.
1 if some of this fototransistors are blocked.
Bit 2: Coin exit phototransistor
Bit 3: String detector mechanism (if the Validator is not programmed in
“L66 compatibility” mode).
Bits 4, 5, 6 and 7: not used = 0