E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 82
The meaning of the data transmitted by the Validator is the following:
-
Data 1: Type of Validator. The value transmitted by the A6-cctalk validator is the
character ‘8’.
-
Data 2: Type of sensor system the Sensor module has. The most usual values are the
following:
-
‘E’: High performance
-
‘6’: High performance without sound sensor.
-
‘1’: Normal performance.
The returned value in case of error can be:
-
‘0’: The Sensor module does not respond
-
‘F’: The Sensor module has its firmware incomplete.
-
Data 3 – Data 16: Internal Azkoyen reference of the programming of coins of the Sensor
module. It is a 14-character string of the type “332XXXXX-X,vXX”, where X are ASCII
characters.
X = ‘0’ is returned if:
-
The Sensor module has its firmware incomplete, it is not correctly programmed or it
does not respond.
-
The Exit module has its firmware incomplete.
-
Data 17: Adjustments version of the coin programming of the Sensor module. It is a
binary value. This value is 0xFF if:
-
The Sensor module has its firmware incomplete or it does not respond.
-
The Exit module has its firmware incomplete.
-
The Validator is not or bad programmed.
-
Adjustments version is not valid
-
Data 18 – 31: Configuration Name of the Exit module. “00000000-0,v00” is returned if:
-
The Sensor module has its firmware incomplete or it does not respond.
-
The Exit module has its firmware incomplete.
-
The Validator is not or bad programmed.
-
Configuration data are not valid