E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 67
This command requests the Validator for information about the default classification path to
which the coins are sent.
Send:
[Dir] [0] [1] [188] [Chk]
Reply:
[1] [1] [Dir] [0] [Data 1] [Chk] -> ACK with a data
Where
Dir = address of the corresponding validator
Data 1 = Path of the sorter that is taken as default.
The value sent corresponds to that which is programmed using the command MODIFY
DEFAULT SORTER PATH [189].
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded.
b)
The Validator does not answer if it is programmed in “L66 compatibility” mode.
5.48
MODIFY COIN ID [185]
Command not available in “Secure Mode”.
With this command each coin is assigned an identity (6 characters maximum):
Send:
[Dir] [7] [1] [185] [Data 1][char 1] [char 2] [char 3] [char 4] [char 5]
[char 6] [Chk]
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data
Where
Dir = address of the corresponding validator
Data 1 Position of the coin (1 a 16)
Data 2 ... Data 6: ASCII characters of the coin identity
Each coin in the Validator is assigned a 6-character identity, which can be modified with this
command and read using the command REQUEST COIN ID [184]. The identities are kept in the
Flash memory of the Validator.