E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 41
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data
Where
Dir = address of the corresponding validator
Only bit 0 of Data1 is used.
Data1.bit0 = 0: Inhibit activated, coins not accepted
Data1.bit0 = 1: Normal working mode.
The “Master Inhibit” bit is saved in RAM and is reset to 1 on reset or power-up.
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded
b)
The Validator does not answer if it is programmed in “L66 compatibility” mode.
5.22
REQUEST MASTER INHIBIT STATUS [227]
This command is not available if the Validator is programmed in “L66 compatibility” mode.
Request information from the validator about of the present state of the “Master Inhibit” bit:
Send:
[Dir] [0] [2] [227] [Chk]
Reply:
[1] [1] [Dir] [0] [Data 1][Chk] -> ACK with 1 data.
Where
Dir = address of the corresponding validator
Data1.bit0 = 0: Inhibit activated, coins not accepted
Data1.bit0 = 1: Normal working mode.
This bit is modified using the command MODIFY MODIFY MASTER INHIBIT STATUS [228].
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded