E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 65
Notes:
a)
A NACK is returned if something of the following occurs:
the Exit module does not have its software correctly loaded or does not have its tables
correctly programmed
The Sensor module does not answer, its software is not correctly loaded or its tables are
not correctly programmed.
The coin tables of the Exits module and the Sensor Module are not coincident or are not
compatible.
Example:The Machine requests to the Validator number 2 its build code, which in this example
is “41123121-0”
Send:
[2] [0] [1] [192] [613]
Reply:
[01] [10] [2] [00] [‘4’] [‘1’] [‘1’] [‘2’] [‘3’] [‘1’] [‘2’] [‘1’] [‘-‘] [‘0’] [chk]
Note: the reference “41123121-0” is only an example, is does not correspond to any real
reference number.
5.46
MODIFY DEFAULT SORTER PATH [189]
This command is not available if the Validator is programmed in “L66 compatibility” mode.
The machine communicates to the Validator the default classification path to which the coins
are sent.
Send:
[Dir] [1] [1] [189] [Data 1] [Chk]
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data
Where
Dir = address of the corresponding validator
Data 1 = The default path of the sorter that the validator should send the coins.