E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 45
The value of the default classification path is indicated to the Validator using the command
MODIFY DEFAULT SORTER PATH [189].
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded..
b)
The Validator does not answer if it is programmed in “L66 compatibility” mode.
Example:
The Machine sends the following information about the paths permitted of classification to
Validator number 2:
- Paths 1 and 3: permitted
- Rest of paths: prohibited:
The value transmitted will be (in binary): 0000.0101 = 5 (decimal)
Send:
[2] [1] [1] [222] [5] [25]
Reply:
[1] [0] [2] [0] [253]
5.26
REQUEST SORTER OVERRIDE STATUS [221]
This command is not available if the Validator is programmed in “L66 compatibility” mode.
The Machine requests the Validator for information about the classification paths that are
permitted.
Send:
[Dir] [0] [1] [221] [Chk]
Reply:
[1] [1] [Dir] [0] [Data 1] [Chk] -> ACK with a data
Where
Dir = address of the corresponding validator
Data 1 = a set of bits that indicates the path permitted:
Data 1. Bit0 = Path 1
Data 1. Bit1 = Path 2
...........