E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 29
-
Product code: same string that the command REQUEST PRODUCT CODE [244] returns,
followed by the string “ cctalk”.
-
String ‘Vxx.y’ indicating the software version of the Exit module. ‘xx’ corresponds to the
version. ‘.’ is a separator. ‘y’ corresponds to the subversion.
The string with the product code has the same restrictions as the command REQUEST
PRODUCT CODE [244].
Command protected by a PIN.
Example:
The Machine requests Validator number 2 for its software version, which in this example is ‘X6
cctalk V1.2’.
Send:
[2] [0] [1] [241] [12]
Reply:
[1] [14] [2] [0] [‘X’] [‘6’] [‘ ‘] [‘c’] [‘c’] [‘t’] [‘a’] [‘l’] [‘k’] [‘ ‘] [‘V’] [‘1’] [‘.’]
[‘2’] [chk]
5.14
TEST SOLENOIDS [240]
Using this command the different solenoids of the validator are activated for a determined
time: The acceptance gate and 3 sorter solenoids. The bit mask that is sent indicates which
solenoids are activated.
Send:
[Dir] [1] [1] [240] [Data 1] [Chk]
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data
Where
Dir = address of the corresponding Validator
[Data 1] = Bit mask of solenoid activation
Bit 0 – Acceptance gate solenoid
Bit 1 – Sorter solenoid 1
Bit 2 – Sorter solenoid 2
Bit 3 – Sorter solenoid 3