Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-30
16. CONFigure:MSTSLV
Description: It executes the Master/Slave control.
Syntax:
CONFigure:MSTSLV ON
CONFigure:MSTSLV OFF
Parameter: ON | OFF
Example:
CONFigure:MSTSLV ON
CONFigure:MSTSLV OFF
Query Syntax:
CONFigure:MSTSLV?
Return Parameter: ON| OFF
Query Example:
CONF:MSTSLV?
Return Example:
ON| OFF
Note
1.
Set the following 3 commands before controlling this function:
CONFigure:MSTSLV:ID
ONFigure:MSTSLV:PARSER
CONFigure:MSTSLV:NUMSLV
2.
The series/parallel control is not available when Program RUN is executed.
To set the series/parallel control, it needs to release the Program Mode
first.
17. CONFigure:INHibit
Description: It enables the Remote Inhibit control.
Syntax:
CONFigure:INHibit <ARG>
Parameter: DISABLE| ENABLE
Example:
CONFigure:INHibit DISABLE
CONFigure:INHibit ENABLE
Query Syntax:
CONFigure:INHibit?
Return Parameter: DISABLE | ENABLE
Query Example:
CONF:INH?
Return Example:
DISABLE
18. CONFigure:INHibit:PULL
Description: It controls the internal resistance status of Remote Inhibit input
signal.
Syntax:
CONFigure:INHibit:PULL <ARG>
Parameter: LOW|HIGH
Example:
CONFigure:INHibit:PULL LOW
CONFigure:INHibit:PULL HIGH
Query Syntax:
CONFigure:INHibit:PULL?
Return Parameter: LOW | HIGH
Query Example:
CONF:INH:PULL?
Return Example:
LOW
19. CONFigure:INTERLOCK
Description: It enables the Safety Interlock control.
Syntax:
CONFigure:INTERLOCK <ARG>
Parameter: DISABLE| ENABLE
Example:
CONFigure:INTERLOCK DISABLE
CONFigure:INTERLOCK ENABLE
Query Syntax:
CONFigure:INTERLOCK?
Return Parameter: DISABLE | ENABLE
Query Example:
CONF:INTERLOCK?
Return Example:
DISABLE