Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-42
5.6.2.7
IV Subsystem
1.
IVCurve:VOC?
Description:
It queries the VOC in IV Curve Mode.
Query Syntax:
IVCurve:VOC ?
Return Parameter: <NRf+>
Query Example: IVCurve:VOC ?
Return Example:
6.02
2.
IVCurve:ISC?
Description:
It queries the ISC in IV Curve Mode.
Query Syntax:
IVCurve:ISC ?
Return Parameter: <NRf+>
Query Example: IVCurve:ISC ?
Return Example:
8.00
3.
IVCurve:VMPp?
Description:
It queries the VMPp in IV Curve Mode.
Query Syntax:
IVCurve:VMPp?
Return Parameter: <NRf+>
Query Example: IVCurve:VMPp?
Return Example:
5.02
4.
IVCurve:IMPp?
Description:
It queries the IMPp in IV Curve Mode.
Query Syntax:
IVCurve:IMPp?
Return Parameter: <NRf+>
Query Example: IVCurve:IMPp?
Return Example:
5.00
5.
IVCurve:PMPp?
Description:
It queries the PMPp in IV Curve Mode.
Query Syntax:
IVCurve:PMPp?
Return Parameter: <NRf+>
Query Example: IVCurve:PMPp?
Return Example:
5.01
6.
IVCurve:VT
Description:
It sets the stored 128 dots voltage data in IV Curve Mode.
Syntax:
IVCurve:VT <NRf+>...< NRf+>
Example:
It sets the voltage table of IV Curve data.
IVCurve:VT <V1>,<V2,...<V128>
Query Syntax:
IVCurve:VT?
Return Parameter: <NRf+>,...,<NRf+>
Query Example: IVCurve:VT?
Return Example:
<V1>,<V2>,...<V128>
Note
The execution time of this command is longer in Master/Slave mode. To
ensure normal operation, it is necessary to use the *OPC command. It will run
the next command after the *OPC command responded.
Ex.: IVC:VT xxx,xxx,xxx,...
*OPC?