Lantronix
SISPM1040-582-LRT CLI Reference
33757 Rev. J
Page
166
of
272
Command
:
logging
Description
:
Show System logging messages.
Syntax
:
show
logging <log_id> [ switch <switch_list> ]
show
logging [ info ] [ warning ] [ error ] [ emerg ] [ alert ] [ crit ] [ notice ] [ debug ] [ switch <switch_list> ]
[ reverse ]
show
logging flash [ category { debug | system | application } ] [ level { informational | notice | warning | error } ]
Parameters
:
<1-4294967295> Logging ID
alert Severity 1: Action must be taken immediately
crit Severity 2: Critical conditions
debug Severity 7: Debug-level messages
emerg Severity 0: System is unusable
error Severity 3: Error conditions
flash Logging message on Flash
info Severity 6: Informational messages
notice Severity 5: Normal but significant condition
warning Severity 4: Warning conditions
exclude
Exclude lines that match
include
Include lines that match
<line>
String to match output lines
<line>
String to match input lines
switch
Switch
category
Category of logging message
level
Severity level
application
Application category
debug
Debug category
system
System category
<switch_list>
Switch ID list in 1
Example 1
:
SISPM1040-582-LRT#
show logging 5
Switch : 1
ID : 5
Level : Warning
Time : 2011-01-01T00:00:10+00:00
Message:
DI 1 change to abnormal
SISPM1040-582-LRT#
show logging crit
Switch logging host mode is disabled
Switch logging host address is null
Switch logging host port is 514
Number of entries on Switch 1:
Emerg : 0
Alert : 0
Crit : 0
Error : 0
Warning : 14
Notice : 2
Info : 10
Debug : 0
All : 26