User Manual
UMN:CLI
V5824G
529
To display the uplink MAC learning status of ONU, use the following command.
Command
Mode
Description
show onu switch-control
ONU-
ID
GPON-OLT
Shows the uplink MAC learning status of ONU
’s uplink
port.
11.3.2.8
GPON Optic Module Threshold of ONU
The ONU
’s GPON optic module can operate depending on monitoring type of
temperature, RX/TX power, voltage or Txbias. To set the threshold of GPON optical
transceiver of ONU, use the following command.
Command
Mode
Description
ani-rx-power
threshold
{
low
VALUE
[
high
VALUE
]
|
high
VALUE
[
low
VALUE
] }
ONU-Profile
Configures the RX optical power threshold and sends
the configured threshold value to ONUs. The ONUs
monitors the change of values and sends RX power
high/low alarm to OLT when the RX power exceeds the
threshold or it is below the threshold.
VALUE: RX power threshold value ( -127 to 0 dBm)
ani-tx-power
threshold
{
low
VALUE
[
high
VALUE
]
|
high
VALUE
[
low
VALUE
] }
Configures the TX optical power threshold and sends
the configured threshold value to ONUs. The ONUs
monitors the change of values and sends TX power
high/low alarm to OLT when the TX power exceeds the
threshold or it is below the threshold.
VALUE: TX power threshold value ( -127 to 0 dBm)
ani-temperature threshold
{
low
VALUE
[
high
VALUE
]
|
high
VALUE
[
low
VALUE
] }
Configures the temperature threshold and sends the
configured threshold value to ONUs. The ONUs
monitors the change of values and sends temperature
high/low alarm to OLT when the temperature exceeds
the threshold or it is below the threshold.
VALUE: temperature threshold value ( -128
∼
127
℃)
ani-tx-bias
threshold
{
low
VALUE
[
high
VALUE
]
|
high
VALUE
[
low
VALUE
] }
Configures the txbias threshold and sends the
configured threshold value to ONUs. The ONUs
monitors the change of values and sends txbias
high/low alarm to OLT when the txbias exceeds the
threshold or it is below the threshold.
VALUE: tx-bias threshold value (0
∼
131
mA)
ani-voltage
threshold
{
low
VALUE
[
high
VALUE
]
|
high
VALUE
[
low
VALUE
] }
Configures the voltage threshold and sends the
configured threshold value to ONUs. The ONUs
monitors the change of values and sends voltage
high/low alarm to OLT when the voltage exceeds the
threshold or it is below the threshold.
VALUE: voltage threshold value ( 0
∼
10.0 V)