Enter 182 End
*/$%ENTR* *ZEND*
Setting up your Operation Modes
7
7-4-2-15.
Set Pairing Timeout
Pairing Timeout refers to an amount of time allocated to the scanner for pairing with other
Bluetooth devices. When timeout period expires yet the Bluetooth connection is not
established, the pairing process will terminate due to the failed attempt. Please follow the
below steps to configure pairing timeout.
Procedure
(1) Scan
Enter
barcode.
(2) Scan
PairingTime
barcode to configure Pairing Timeout.
(3) Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to set
pairing timeout to be 20 seconds, scan
2
first and then
0
to assign the specified decimal
value “20”.
(4) Scan
SET
barcode to complete the variable-binding operation.
(5) Scan
End
barcode to complete the configuration.
7-4-2-16.
Set Good Read Buzzer Frequency
Please follow the below steps to specify the buzzer frequency when a barcode is decoded
successfully.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
BzGoodRdFreq
barcode to configure Good Read buzzer frequency.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
set Good Read buzzer frequency to 10000 Hz, scan
1, 0
and then
0
to assign the
specified decimal value “100”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*BF5E0*
BzGoodRdFreq
BF5E0
*BF4E0*
PairingTime
BF4E0
(Length: 1 digit / Range: 30-255/ Unit: 1000ms)
(Length: 1 digit / Range: 1-50/ Unit: 100Hz)