Enter 227 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
8-11-13.
Set Length Scale
Length scale have to work collaboratively with length qualification which is illustrated in
Section 8-11-8. For the reason, three length variables are available for you to further
associate with the desired values. Depending on the type of qualification you select, length
variables can have different meanings. With
Min
length condition,
Code128Len1
variable
represents the minimum size to limit the minimum length of a valid barcode. On the other
hand, with
Min/Max
length condition, the barcode will be decoded only if its length has to
fall within the range of
Code128Len1
to
Code128Len2
.
In this case,
Code128Len1
stands
for the minimum and
Code128Len2
for the maximum. However,
Code128Len1,
Code128Len2,
and
Code128Len3
can also represent a group of length limits when
Fixed
length qualification is chosen. It means the scanner will only decode the barcode with the
length which agrees with
Code128Len1, Code128Len2, or Code128Len3.
3-5
. Set Length2 variable
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
Code128Len1
barcode to determine the value of the length variable.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal
value barcodes representing the desired number in the range of 0 to 255. For
instance, to set its length to be 8, then scan
8
to assign the specified decimal
value “8”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Repeat Steps 2-4 for Code128Len2 and Code128Len3, if necessary.
(6)
Scan
End
barcode to complete the configuration.
*43501*
Code128Len1
43501
*43511*
Code128Len2
43511
*43521*
Code128Len3
43521
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)