Enter 220 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
Code93UDSI
barcode to tailor Code ID for Code93 to your needs.
(3)
Please refer to ASCII Code Table and Decimal/Hexadecimal Table in the appendix
to scan hexadecimal value barcodes representing the desired string which has to be
at most 2 characters in length. For instance, to set its Code ID to be “93”, scan
3, 9,
3,
and then
3
to assign the specified hexadecimal value “3933”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
8-10-4.
Set Length Scale
Length scale have to work collaboratively with length qualification which is illustrated in
Section 8-10-2. For the reason, three length variables are available for you to further
associate with the desired values. Depending on the type of qualification you select, length
variables can have different meanings. With
Min
length condition,
Code93Len1
variable
represents the minimum size to limit the minimum length of a valid barcode. On the other
hand, with
Min/Max
length condition, the barcode will be decoded only if its length has to
fall within the range of
Code93Len1
to
Code93Len2
.
In this case,
Code93Len1
stands for
the minimum and
Code93Len2
for the maximum. However,
Code93Len1, Code93Len2,
and
Code93Len3
can also represent a group of length limits when
Fixed
length qualification
is chosen. It means the scanner will only decode the barcode with the length which agrees
with
Code93Len1, Code93Len2, or Code93Len3.
3-5
*41C02*
Code93UDSI
41C02
*41501*
Code93Len1
41501
*41511*
Code93Len2
41511
*41521*
Code93Len3
41521
(Length: 2 digits)
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)