Enter 118 End
*/$%ENTR* *ZEND*
Setting up your Operation Modes
7
7-2-2-15.
Set Good Read Buzzer Frequency
Please follow the below steps to specify Good Read Buzzer frequency when a barcode is
decoded successfully.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
BzGoodRdFreq
barcode to configure Good Read buzzer frequency.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
set Good Read buzzer frequency to 10000 Hz, scan
1, 0
and then
0
to assign the
specified decimal value “100”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
7-2-2-16.
Set Good Read Buzzer Duration
Please follow the below steps to specify Good Read Buzzer duration when a barcode is
decoded successfully.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
BzGoodRdTime
barcode to configure Good Read buzzer duration.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
set Good Read buzzer duration for 0.2 seconds, scan
2
first and then
0
to assign the
specified decimal value “20”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*B35E0*
BzGoodRdFreq
B35E0
*B36E0*
BzGoodRdTime
B36E0
(Length: 1 digit / Range: 1-50/ Unit: 100 Hz)
(Length: 1 digit / Range: 1-255/ Unit: 10ms)