clock summer-time date
This command defines the start and end of summertime for a specific year only, and specifies
summertime’s offset value to Standard Time for that year.
The
no
parameter removes the device’s summertime setting. This clears both specific
summertime dates and recurring dates (set with the
clock summer-time recurring command
on page 8.5
).
By default, the device has no summertime definitions set.
Syntax
clock summer-time ZONENAME date START-DAY START-MONTH START-YEAR
START-TIME END-DAY END-MONTH END-YEAR END-TIME <1-180>
no clock summer-time
Mode
Configure mode.
Examples
To set a summertime definition for New Zealand using NZST (UTC+12:00) as the standard
time, and NZDT (UTC+13:00) as summertime, with the summertime set to begin on the 1st
October 2007 and end on the 18th of March 2008:
To remove any summertime settings on the system, use the command:
awplus(config)#
no clock summer-time
Related Commands
clock summer-time recurring
clock timezone
show clock
Parameter
Description
ZONENAME
A description of the summertime zone, up to 6 characters long.
date
Specifies that this is a date-based summertime setting for just the specified
year.
START-DAY
Day that the summertime starts, in the range 1-31.
START-MONTH
First three letters of the name of the month that the summertime starts.
START-YEAR
Year that summertime starts, in the range 2000-2035.
START-TIME
Time of the day that summertime starts, in the 24-hour time format
HH:MM.
END-DAY
Day that summertime ends, in the range 1-31.
END-MONTH
First three letters of the name of the month that the summertime ends.
END-YEAR
Year that summertime ends, in the range 2000-2035.
END-TIME
Time of the day that summertime ends, in the 24-hour time format
HH:MM.
<1-180>
The offset in minutes.
awplus(config)#
clock summer-time NZDT date 1 oct 2:00
2007 18 mar 2:00 2008 60