802.1x and RADIUS Commands
©2008 Allied Telesis Inc. All rights reserved.
42.8
AlliedWare Plus
TM
Operating System Software Reference C613-50003-00 REV E
Software Version 5.2.1
dot1x timeout supp-timeout
Use this command to set the interval for a supplicant to respond.
Syntax
dot1x timeout supp-timeout <
seconds
>
Mode
Interface mode
Default
The default supplicant response timeout is 30 seconds.
Examples
awplus#configure terminal
awplus(config)#interface port1.0.1
awplus(config-if)#dot1x timeout supp-timeout 40
dot1x timeout tx-period
Use this command to set the interval between successive attempts to request an ID.
Syntax
dot1x timeout tx-period <
seconds
>
Mode
Interface mode
Default
The default period between successive request ID attempts is 30 seconds.
Examples
awplus#configure terminal
awplus(config)#interface port1.0.1
awplus(config-if)#dot1x timeout tx-period 34
Parameter
Description
<
period
>
<1-65535> Seconds.
Specify the supplicant response timeout in seconds
The default timeout is 30 seconds.
Parameter
Description
<
seconds
>
<1-65535> Seconds.
Specify the period in seconds between successive request ID attempts.
The default timeout period is 30 seconds.