Chapter 5 Instruction Specifications
5-17
Item number
Basic instructions-7
Name
Negation (NOT)
Ladder format
Condition code
Processing time (
µ
s)
Remark
R7F4
R7F3
R7F2
R7F1
R7F0
Average Maximum
DER
ERR
SD
V
C
z
z
z
z
z
Instruction format
Number of steps
0.8
Condition
Steps
NOT
2
Bit
Word
Double word
Usable I/O
X
Y
R,
M
TD, SS,
CU, CT
WX WY
WR,
WM TC DX DY
DR,
DM
C
o
nstant
Other
Function
•
Reverses the operation result obtained up to that point.
Program example
X00000
R100
LD
AND
NOT
OUT
X00000
X00001
R100
X00001
Program description
•
When input X00000 and input X00001 are both on, the operation is “1,” but due to
, the calculation turns into “0”
and R100 turns off.
•
In all other cases, R100 turns on.