Parameter Description
Parameters
93
Item
Shihlin
protocol
Reference
code
Modbus
Reference
code
Modbus
address
Data content and function description
Parameter read-out
H00~H63
H03
H0000
|
H02BB
For P.0~P.699, the data range and the
position of the decimal point, please
refer to the parameter table. The
MODBUS address of each parameter
corresponds to the hexadecimal digit
of the parameter number. For
example, the MODBUS address
of P.138 is H008A.
Parameter write-in
H80~HE3
H06/H10
Line speed feedback
read-out
---
H03
H100A
H0000~HFDE8
Line speed feedback
write-in
H06/H10
Line speed target
value read-out
---
H03
H100B
H0000~HFDE8
Line speed target
value write-in
H06/H10
Tension reference
read-out
---
H03
H100C
H0000~H7530
Tension reference
write-in
H06/H10
Torque reference
read-out
---
H03
H100D
H0000~H2710 (0~100.00%)
HD8F0~HFFFF(-100.00%~0)
Torque reference
write-in
H06/H10
Page change
for parameter
reading and
writing
Read
H7F
---
---
H0000
:
P.0~P.99
;
H0001
:
P.100~P.199
;
H0002
:
P.200~P.299
;
H0003
:
P.300~P.399
;
H0004
:
P.400~P.499
;
H0005
:
P.500~P.599
;
H0006
:
P.600~P.699
。
Write
HFF
Loopback test for
asynchronous serial
communication
---
H08
H0000
(sub function
code for
loopback
test)
The
content value is arbitrary
(H0000~HFFFF)