Settings
EFORT INTELLIGENT EQUIPMENT CO.,LTD
97
pulse signals that control
the
movement
of
asynchronous axis will be
shielded.
(Note: See I/O setting
function for configuration
methods.)
Synchronous and Asynchronous Switching Online
Procedures of Synchronous and Asynchronous Command Switching Online
#
Dementration
Remarks
1
①
Synchronous
axis
movement command;
②
Clear the flag bit of the
synchronous axis;
③
Asynchronous axis running
signal;
④
Make
sure
the
asynchronous axis is running,
and add a waiting signal.
Descriptions of synchronous and asynchronous switching online:
(1) During the running of synchronous axis, all asynchronous axis requests will n
ot be responded.
(2) During the running of asynchronous axis, the asynchronous axis running com
mand will be interrupted until there is a request of synchronous non-interpolated axis.
When switching the synchronous interpolated axis to the asynchronous axis
:
(1) auxj.ClearAuxMask() do not need to be executed, if the smooth transition co
mmand is fine (namely, there is no smooth transition) or the following command is
MJOINT(POINTJ/POINTC).
(2) It is necessary to execute the command to clear the flag bit after the complet
ion of synchronous axis movement, if the circular arc transition command is of zone t
ype (z50, etc.) and it is followed by a signal of asynchronous axis movement, that is,
auxj.AuxMoveStep().