Bit
Name
Reset
Access Description
31:19
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
18
CLERR
0
(R)W1
Clear CLERR Interrupt Flag
Write 1 to clear the CLERR interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
17
RXFULL
0
(R)W1
Clear RXFULL Interrupt Flag
Write 1 to clear the RXFULL interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
16
SSTOP
0
(R)W1
Clear SSTOP Interrupt Flag
Write 1 to clear the SSTOP interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
15
CLTO
0
(R)W1
Clear CLTO Interrupt Flag
Write 1 to clear the CLTO interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
14
BITO
0
(R)W1
Clear BITO Interrupt Flag
Write 1 to clear the BITO interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
13
RXUF
0
(R)W1
Clear RXUF Interrupt Flag
Write 1 to clear the RXUF interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
12
TXOF
0
(R)W1
Clear TXOF Interrupt Flag
Write 1 to clear the TXOF interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
11
BUSHOLD
0
(R)W1
Clear BUSHOLD Interrupt Flag
Write 1 to clear the BUSHOLD interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt
flags (This feature must be enabled globally in MSC.).
10
BUSERR
0
(R)W1
Clear BUSERR Interrupt Flag
Write 1 to clear the BUSERR interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
9
ARBLOST
0
(R)W1
Clear ARBLOST Interrupt Flag
Write 1 to clear the ARBLOST interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
8
MSTOP
0
(R)W1
Clear MSTOP Interrupt Flag
Write 1 to clear the MSTOP interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
7
NACK
0
(R)W1
Clear NACK Interrupt Flag
Write 1 to clear the NACK interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
6
ACK
0
(R)W1
Clear ACK Interrupt Flag
Write 1 to clear the ACK interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags (This
feature must be enabled globally in MSC.).
5:4
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
3
TXC
0
(R)W1
Clear TXC Interrupt Flag
EFM32JG1 Reference Manual
I2C - Inter-Integrated Circuit Interface
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 439