17.5.10 LEUARTn_TXDATAX - Transmit Buffer Data Extended Register (Async Reg)
For More information about Registers please see
4.3 Access to Low Energy Peripherals (Asynchronous Registers)
Offset
Bit Position
0x024
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0x000
Access
W
W
W
W
Name
Bit
Name
Reset
Access Description
31:16
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
15
RXENAT
0
W
Enable RX After Transmission
Set to enable reception after transmission.
Value
Description
0
The receiver is not enabled after the frame has been transmitted
1
The receiver is enabled (setting RXENS) after the frame has been
transmitted
14
TXDISAT
0
W
Disable TX After Transmission
Set to disable transmitter directly after transmission has competed.
Value
Description
0
The transmitter is not disabled after the frame has been transmitted
1
The transmitter is disabled (clearing TXENS) after the frame has been
transmitted
13
TXBREAK
0
W
Transmit Data As Break
Set to send data as a break. Recipient will see a framing error or a break condition depending on its configuration and the
value of TXDATA.
Value
Description
0
The specified number of stop-bits are transmitted
1
Instead of the ordinary stop-bits, 0 is transmitted to generate a break. A
single stop-bit is generated after the break to allow the receiver to de-
tect the start of the next frame
12:9
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
8:0
TXDATA
0x000
W
TX Data
Use this register to write data to the LEUART. If the transmitter is enabled, a transfer will be initiated at the first opportunity.
EFM32JG1 Reference Manual
LEUART - Low Energy Universal Asynchronous Receiver/Transmitter
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 564