9.5.7 EMU_TEMPLIMITS - Temperature limits for interrupt generation
Offset
Bit Position
0x01C
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0xFF
0x00
Access
R
W
R
W
R
W
Name
Bit
Name
Reset
Access Description
31:17
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
16
EM4WUEN
0
RW
Enable EM4 Wakeup due to low/high temperature
Enable EM4 wakeup from low or high temperature from EM4H
15:8
TEMPHIGH
0xFF
RW
Temperature High Limit
The TEMPHIGH interrupt flag is set when a periodic temperature measurement is equal to or higher than this value. If the
high limit is changed during a temperature measurement (TEMPACTIVE=1), the limit update will be delayed until the end of
the temperature measurement.
7:0
TEMPLOW
0x00
RW
Temperature Low Limit
The TEMPLOW interrupt flag is set when a periodic temperature measurement is equal to or lower than this value. If the
low limit is changed during a temperature measurement (TEMPACTIVE=1), the limit update will be delayed until the end of
the temperature measurement.
9.5.8 EMU_TEMP - Value of last temperature measurement
Offset
Bit Position
0x020
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0xXX
Access
R
Name
Bit
Name
Reset
Access Description
31:8
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
7:0
TEMP
0xXX
R
Temperature Measurement
Value of last periodic temperature measurement. Value is asynchronously updated. Value is stable for 250 ms after a tem-
perature-based interrupt (TEMPHIGH, TEMPLOW, or TEMP) and can be read with a single read operation. If register is
read not in response to a temperature-based interrupt, multiple readings should be taken until two consecutive values are
the same.
EFM32JG1 Reference Manual
EMU - Energy Management Unit
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 177