22.5.3 ADCn_STATUS - Status Register
Offset
Bit Position
0x00C
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0x0
0
0
0
0
Access
R
R
R
R
R
R
R
R
Name
Bit
Name
Reset
Access Description
31:18
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
17
SCANDV
0
R
Scan Data Valid
SCANCTRLX_DVL # of scan conversion data results are available in Scan FIFO.
16
SINGLEDV
0
R
Single Channel Data Valid
SINGLECTRLX_DVL # of single channel conversion results are available in Single FIFO.
15:13
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
12
WARM
0
R
ADC Warmed Up
ADC is warmed up.
11:10
PROGERR
0x0
R
Programming Error Status
Programming Error Status
Mode
Value
Description
BUSCONF
x1
APORT reported a BUS Conflict.
NEGSELCONF
1x
SINGLECTRL's NEGSEL choice is invalid with respect to POSSEL
choice. Occurs when two X channels or two Y channels are selected.
9
SCANREFWARM
0
R
Scan Reference Warmed Up
Reference selected for scan mode is warmed up.
8
SINGLEREFWARM
0
R
Single Channel Reference Warmed Up
Reference selected for single channel mode is warmed up.
7:2
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
1
SCANACT
0
R
Scan Conversion Active
Scan sequence is active or has pending conversions.
0
SINGLEACT
0
R
Single Channel Conversion Active
Single channel conversion is active or has pending conversions.
EFM32JG1 Reference Manual
ADC - Analog to Digital Converter
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 746