Bit
Name
Reset
Access Description
31:26
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
25
PROGERR
0
R
Programming Error Interrupt Flag
Indicates that a programming error has occurred. Read the STATUS register for cause.
24
VREFOV
0
R
VREF Over Voltage Interrupt Flag
Indicates that attenuated vref is greater than 1.3V when this bit is set. The ADC stops converting and disconnects the refer-
ence when this happens to protect the internal low-voltage circuits.
23:18
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
17
SCANCMP
0
R
Scan Result Compare Match Interrupt Flag
Indicates scan result compare matched the window conditions when this bit is set.
16
SINGLECMP
0
R
Single Result Compare Match Interrupt Flag
Indicates single result compare matched the window conditions when this bit is set.
15:12
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
11
SCANUF
0
R
Scan FIFO Underflow Interrupt Flag
Indicates scan result FIFO underflow when this bit is set. An underflow occurs if the FIFO is read and there is no data avail-
able.
10
SINGLEUF
0
R
Single FIFO Underflow Interrupt Flag
Indicates single result FIFO underflow when this bit is set. An underflow occurs if the FIFO is read and there is no data
available.
9
SCANOF
0
R
Scan FIFO Overflow Interrupt Flag
Indicates scan result FIFO overflow when this bit is set. An overflow occurs if there is not room in the FIFO to store a new
result.
8
SINGLEOF
0
R
Single FIFO Overflow Interrupt Flag
Indicates single result FIFO overflow when this bit is set. An overflow occurs if there is not room in the FIFO to store a new
result.
7:2
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
1
SCAN
0
R
Scan Conversion Complete Interrupt Flag
Indicates (DVL+1) number of scan channel results are available in the Scan FIFO.
0
SINGLE
0
R
Single Conversion Complete Interrupt Flag
Indicates (DVL+1) number of single channel results are available in the Single FIFO.
EFM32JG1 Reference Manual
ADC - Analog to Digital Converter
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 775