#TEMPMON - Temperature Monitor
AT#TEMPMON=
<mod>
[,<urcmode>
[,<action>
[,<hyst_time>
[,<GPIO>]]]]
Set command sets the behavior of the module internal temperature monitor.
Parameters:
<mod>
0 - sets the command parameters.
1 - triggers the measurement of the module internal temperature, reporting
the result in the format:
#TEMPMEAS: <level>,<value>
where:
<level>
- threshold level
-2 - extreme temperature lower bound (see Note)
-1 - operating temperature lower bound (see Note)
0 - normal temperature
1 - operating temperature upper bound (see Note)
2 - extreme temperature upper bound (see Note)
<value>
actual temperature expressed in Celsius degrees
Setting of the following optional parameters has meaning only if
<mod>=0:
<urcmode> -
URC presentation mode.
(Default 0)
0 - it disables the presentation of the temperature monitor URC
1 - it enables the presentation of the temperature monitor URC, whenever
the module internal temperature reaches either operating or extreme
levels;
the unsolicited message is in the format:
#TEMPMEAS: <level>,<value>
where:
<level>
and
<value>
are as before
<action>
- sum of integers, each representing the action to be done whenever
the module internal temperature reaches either operating or extreme