LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 154 of 273
#CBC- Battery And Charger Status
where:
<ChargerState>
- battery charger state
0 - charger not connected
1 - charger connected and charging
2 - charger connected and charge completed
<BatteryVoltage>
- battery voltage in millivolt: it is the real battery voltage only if
charger is not connected; if the charger is connected this value depends on the
charger voltage.
NOTE: ‘1’ and ‘2’ at <ChargerState> is not supported.
AT#CBC=?
Test command returns the
OK
result code.
#MONI - Cell Monitor
AT#MONI[=
[<number>]]
Set command sets one cell out of seven, in a neighbour of the serving cell
including it, from which extract E-UTRAN-related information.
Parameter:
<number>
<E-UTRAN>
0
– it is the serving cell
1
– it is the intra-frequency cells
2
– it is the inter-frequency cells
3
– it is the WCDMA neighbour cells
4
– it is the GSM neighbour cells
3..7
– it is not available
AT#MONI
Read command reports the following E-UTRAN-related information for selected
cell and dedicated channel (if exists).
a) When extracting data for the serving cell and the network name is known the
format is:
(E-UTRAN)
#MONI: <netmame> RSRP:<rsrp> RSRQ:<rsrq> TAC:<tac> Id:<id>
EARFCN:<earfcn> PWR:<dBm> DRX:<drx>
b)
When the network name is unknown, the format is:
(E-UTRAN)
#MONI: Cc:<cc> Nc:<nc> RSRP:<rsrp> RSRQ:<rsrq> TAC:<tac> Id:<id>
EARFCN:<earfcn> PWR:<dBm> DRX:<drx>
c) When extracting data for an adjacent cell, the format is:
(E-UTRAN)
(E-UTRAN intra-frequency and inter-frequency cells)
#MONI: RSRP:<rsrp> RSRQ:<rsrq> Id:<id> EARFCN:<earfcn>
Summary of Contents for LE910-SKG
Page 1: ......