LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 84 of 273
#CPBGR- Read Group Entries
<tlength>
- maximum
<text>
field length, integer type
#CPBGW - Write Group Entry
AT#CPBGW=
<index>,<text>
Execution command writes Grouping information Alpha String (GAS) USIM file
entry in location number
<index>
.
Parameters:
<index>
- integer type, value in the range of location numbers of the GAS file.
<text>
- the text associated to the entry, string type
Note: If record number
<index>
already exists, it will be overwritten.
AT#CPBGW=?
Test command
returns location range supported by the current storage as a
compound value, and maximum length of
<text>
field. The format is:
+CPBGW: (list of supported <index>s),<tlength>
where:
<tlength>
- integer type value indicating the maximum length of field
<text> in
bytes; actual maximum number of characters that can be stored
depends upon <text> coding (see +CSCS)
+CCLK - Clock Management
AT+CCLK=<time>
Set command sets the real-time clock of the
ME
.
Parameter:
<time>
- current time as quoted string in the format: "yy/MM/dd,hh:mm:ss±zz"
yy - year (two last digits are mandatory), range is (00..99)
MM - month (two last digits are mandatory), range is (01..12)
dd - day (two last digits are mandatory), available ranges are
(01..28)
(01..29)
(01..30)
(01..31)
hh - hour (two last digits are mandatory), range is (00..23)
mm - minute (two last digits are mandatory), range is (00..59)
ss - seconds (two last digits are mandatory), range is (00..59)
±zz - time zone (indicates the difference, expressed in quarter of an hour, between
the local time and GMT; two last digits are mandatory), range is -47..+48
AT+CCLK?
Read command returns the current setting of the real-time clock, in the format
<time>
.
Summary of Contents for LE910-SKG