LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 68 of 273
+CLCK - Facility Lock/Unlock
AT+CLCK =”AO”,2
+CLCK: <status>,1
+CLCK: <status>,2
+CLCK: <status>,4
+CPWD - Change Facility Password
AT+CPWD=<fac>,
<oldpwd>,
<newpwd>
Execution command changes the password for the facility lock function defined by
command Facility Lock
+CLCK
.
Parameters:
<fac>
- facility
"AB" - All Barring services
(applicable only for
<mode>=0
)
"AC" - All inComing barring services
(applicable only for
<mode>=0
)
"AG" - All outGoing barring services
(applicable only for
<mode>=0
)
"AI" - BAIC (Barr All Incoming Calls)
"AO" - BAOC (Barr All Outgoing Calls)
"IR" - BIC-Roam (Barr Incoming Calls
When Roaming outside the home country)
"OI" - BOIC (Barr Outgoing International Calls)
"OX" - BOIC-exHC (Barr Outgoing International
Calls except to Home Country)
"SC" - SIM (PIN request)
"P2" - SIM PIN2
"PN" - network Personalisation
"PU" - network subset Personalisation
"PP" - service Provider Personalization (refer 3GPP TS 22.022 [33])
"PC" - Corporate Personalization (refer 3GPP TS 22.022 [33])
"PF" - lock Phone to the very First inserted SIM/UICC card (also referred in the
present document as PH-FSIM) (MT asks password when other than the
first SIM/UICC card is inserted)
<oldpwd>
- string type, it shall be the same as password specified for the facility
from the ME user interface or with command
+CPWD
.
<newpwd>
- string type, it is the new password
Note: parameter
<oldpwd>
is the old password while
<newpwd>
is the new one.
AT+CPWD=?
Test command returns a list of pairs
(<fac>
,
<pwdlength>)
which presents the
available facilities and the maximum length of their password (
<pwdlength>
)
Example
AT+CPWD=?
+CPWD: ("AB",4), ("AC",4), ("AG",4), ("AI",4), ("AO",4), ("IR",4), ("OI",4),
("OX",4), ("SC",8), ("PN",8) , ("PU",8), ("PP",8) , ("PC",8) , ("PF",8)
OK
Summary of Contents for LE910-SKG