LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 184 of 273
#SCFGEXT - Socket Configuration Extended
1 - data represented as sequence of hexadecimal numbers (from 00 to FF)
Each octet of the data is given as two IRA character long hexadecimal number
Note: <
keepalive>
has effect only on TCP connections.
Note: these values are automatically saved in NVM
Note: for the behaviour of AT#SL and AT#SLUDP in case of auto-response mode
or in case of no auto-response mode, see the description of the two commands.
AT#SCFGEXT?
Read command returns the current socket extended configuration
parameters values for all the six sockets, in the format:
#SCFGEXT: <connId1>,<srMode1>,<dataMode1>,<keepalive1>,
< ListenAutoRsp1>,0<CR><LF>
...
#SCFGEXT: <connId6>,<srMode6>,<dataMode6>,<keepalive6>
< ListenAutoRsp6>,0
AT#SCFGEXT=?
Test command returns the range of supported values for all the
subparameters
Example
Socket 1 set with data view sring, text data mode and a
keepalive time of 30 minutes.
Socket 3 set with data amount sring, hex data mode and
no keepalive.
at#scfgext?
#SCFGEXT: 1,2,0,30,0,0
#SCFGEXT: 2,0,0,0,0,0
#SCFGEXT: 3,1,1,0,0,0
#SCFGEXT: 4,0,0,0,0,0
#SCFGEXT: 5,0,0,0,0,0
#SCFGEXT: 6,0,0,0,0,0
OK
#SCFGEXT2 - Socket Configuration Extended
AT#SCFGEXT2=
<connId>,
<bufferStart>
[,<abortConnAttempt
>
[, unused_B>
[,<unused_C>
[,<noCarrierMode>]]
]]
Set command sets the socket configuration extended parameters for features not
included in #SCFGEXT command.
Parameters:
<connId>
- socket connection identifier
1..6
<bufferStart>
- Set the sending timeout method based on new data received from
the serial port.
(<txTo> timeout value is set by #SCFG command)
Restart of transmission timer will be done when new data are received from the
serial port.
0 – old behaviour for transmission timer