LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 177 of 273
#LTEBW: <BAND>,<BW>
AT#LTEBW=?
Test command reports the supported range of parameters values.
#
LTEBW: (3, 1-63)
#
LTEBW: (5, 1-15)
#DOMAIN – Set preferred service domain
AT#DOMAIN=
<service_domain>
Execution command sets service_domain_pref value.
Parameters:
< service_domain >
1
– PS Only
2
– CS/PS (factory default)
Note: After execution, module must be reset.
Otherwise, a module doesn’t work by changed value.
AT#DOMAIN?
Read command reports service_domain_pref value.
# DOMAIN : < service_domain >
AT#DOMAIN=?
Test command returns supported values of parameters
< service_domain >
#SS - Socket Status
AT#SS[=<connId>]
Execution command reports the current status of the socket:
Parameters:
<connId> - socket connection identifier
1..6
The response format is:
#SS: <connId>,<state>,<locIP>,<locPort>,<remIP>,<remPort>
where:
<connId>
- socket connection identifier, as before
<state>
- actual state of the socket:
0 - Socket Closed.
1 - Socket with an active data transfer connection.
2 - Socket suspended.
3 - Socket suspended with pending data.
4 - Socket listening.
5 - Socket with an incoming connection. Waiting for the user accept or shutdown