R01UH0823EJ0100 Rev.1.00
Page 1191 of 1823
Jul 31, 2019
RX23W Group
36. CAN Module (RSCAN)
Transmit history function
Stores the history information of transmitted messages.
Bus off recovery mode
selection
Selects a method of returning from bus off state.
ISO 11898-1 compliant
Automatic transition to channel halt mode at bus-off entry
Automatic transition to channel halt mode at bus-off end
Transition to channel halt mode by a program
Transition to the error-active state by a program (forcible return from the bus off state)
Error status monitoring
Monitors CAN protocol errors (stuff error, form error, ACK error, CRC error, bit error, ACK delimiter error,
and bus dominant lock).
Detects error status transitions (error warning, error passive, bus off entry, and bus off recovery)
Reads the error counter.
Monitors DLC errors.
Interrupt source
5 sources
Global (2 sources)
Global receive FIFO interrupt
Global error interrupt
Channel (3 sources/channel)
Channel transmit interrupt
– Transmit complete interrupt
– Transmit abort interrupt
– Transmit/receive FIFO transmit complete interrupt
– Transmit history interrupt
Transmit/receive FIFO receive interrupt
Channel error interrupt
CAN clock source
Peripheral module clock (PCLK), CANMCLK
Test function
Test function for user evaluation
Listen-only mode
Self-test mode 0 (external loopback)
Self-test mode 1 (internal loopback)
RAM test (read/write test)
Low power consumption
Module stop state can be set.
Table 36.1
CAN Module Specifications (2/2)
Item