23.2.14
Timer Synchronous Registers (TSYR)
The TSYR registers select independent operation or synchronous operation of the TCNT counter in MTU0 to MTU4.
A channel performs synchronous operation when the corresponding bit in the TSYR register is set to 1.
SYNCn Bits (Timer Synchronous n Operation) (n = 0 to 4)
Each bit selects whether operation is independent of or synchronized with other channels.
When synchronous operation is selected, the TCNT synchronous setting of multiple channels and synchronous clearing
by counter clearing on another channel are possible.
To set synchronous operation, the SYNCn bits for at least two channels must be set to 1. To set synchronous clearing, in
addition to the SYNCn bit, the TCNT clearing source must also be set the TCR.CCLR[2:0] bits.
Address(es): MTU.TSYR 000D 0A81h
b7
b6
b5
b4
b3
b2
b1
b0
SYNC4 SYNC3
—
—
—
SYNC2 SYNC1 SYNC0
Value after reset:
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b0
Timer Synchronous Operation 0
0: MTU0.TCNT operates independently
(TCNT setting/clearing is not related to other channels)
1: MTU0.TCNT performs synchronous operation.
TCNT synchronous setting/synchronous clearing is enabled
R/W
b1
Timer Synchronous Operation 1
0: MTU1.TCNT operates independently
(TCNT setting/clearing is not related to other channels)
1: MTU1.TCNT performs synchronous operation.
TCNT synchronous setting/synchronous clearing is enabled
R/W
b2
Timer Synchronous Operation 2
0: MTU2.TCNT operates independently
(TCNT setting/clearing is not related to other channels)
1: MTU2.TCNT performs synchronous operation.
TCNT synchronous setting/synchronous clearing is enabled
R/W
b5 to b3
—
Reserved
These bits are read as 0. The write value should be 0.
R/W
b6
Timer Synchronous Operation 3
0: MTU3.TCNT operates independently
(TCNT setting/clearing is not related to other channels).
1: MTU3.TCNT performs synchronous operation.
TCNT synchronous setting/synchronous clearing is enabled.
R/W
b7
Timer Synchronous Operation 4
0: MTU4.TCNT operates independently
(TCNT setting/clearing is not related to other channels).
1: MTU4.TCNT performs synchronous operation.
TCNT synchronous setting/synchronous clearing is enabled.
R/W