(Optional) Specifies the interval at
which to restart the probe as a
number of seconds, minutes, or
hours, where
number
is in the
following ranges:
•
1 to 90
seconds
•
1 to 90
minutes
•
1 to 24
hours
The default is that probes are not
repeated, and there is no default
interval.
repeat every number
{
seconds
|
minutes
|
hours
}
Specifies the number of probes to
run in the range 1
–
100. There is no
default.
count probes
(Optional) Specifies that the
command displays the on-demand
operation ID and exits immediately,
with the operation continuing in the
background.
The default is synchronous and the
operation displays the on-demand
operation ID and all results on the
console when it completes.
asynchronous
Command Default
No on-demand operations are configured or executed.
Command Modes
EXEC (#)
Command History
Modification
Release
This command was introduced.
Release 4.0.0
The
cfm-delay-measurement-v0
keyword was included.
Release 4.3.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
237
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
ethernet sla on-demand operation type cfm-loopback probe