Appendix B. Status, Settings, and Data Table Information (Status/Settings/DTI)
RS232Power
Settings Editor:
RS232 Always On
Keyboard:
Settings (General)
≈ line 20
CRBasic:
variable = settings.keyword
;
SetSettings()
Controls whether the RS-232 port will remain active
even when communication is not taking place. If
RS-232 handshaking is enabled
(
RS232Handshaking
is non-zero), this setting must
be set to
True
.
read/write
BOOLEAN
False
True
or
False
RS232Timeout
Settings Editor:
RS232 Hardware Handshaking
Timeout
Keyboard:
Settings (General)
≈ line 22
CRBasic:
variable = settings.keyword
;
SetSettings()
RS-232 hardware-handshaking timeout. Specifies
the time that the datalogger will wait between
packets if CTS is not asserted.
read/write
IEEE4
tens of ms
0
???
RunSignature
Station Status:
Run Signature
Keyboard:
Status Table
≈ line 12
CRBasic:
variable = settings.keyword
;
SetSettings()
Signature of the binary (compiled) structure of the
running program. Value is independent of comments
or non-functional changes. Often changes with
operating-system changes. See
ProgSignature
(p.
The pre-compiler can get the program text, but
generating the binary signature is not feasible due to
endian, data size, and compiler structure layout
differences between the PC and the CR1000.
read only
LONG
n/a
n/a
Table 182.
Status/Settings/DTI: S
Keyword
Alias,
Access,
Description
Read/Write,
DataType,
Units
Default
Value
Normal
Range
SecsPerRecord()
AKA:
Data-table interval
Keyboard:
DataTableInfo
≈ line 4
CRBasic:
variable = status.keyword
Reports the data-output interval for a data table.
read only
LONG array
seconds
n/a
n/a
Security(1)
Settings Editor:
Security Level 1
AKA:
Security Code 1
Keyboard:
Settings (General)
≈ line 4
CRBasic:
variable = settings.keyword
;
SetSettings()
First level in an array of three security codes. Not
shown if security is enabled.
0
disables all security.
See
Security — Overview
(p. 92).
read/write
LONG
0
0
to
65535
(
0
= deactivated)
Security(2)
Settings Editor:
Security Level 2
AKA:
Security Code 2
Keyboard:
Settings (General)
≈ line 4
CRBasic:
variable = settings.keyword
;
SetSettings()
Second level in an array of three security codes. Not
shown if security is enabled.
0
disables levels 2 and
3. See
Security(1)
(p. 627)
and section
Security —
Overview
(p. 92).
read/write
LONG
0
0
to
65535
(
0
= deactivated)
627
Summary of Contents for CR1000
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 60: ...Section 4 System Quickstart Figure 16 PC200W View Line Graph 60 ...
Page 96: ......
Page 98: ...98 ...
Page 302: ......
Page 453: ...Section 8 Operation Figure 115 Using the Keyboard Display 453 ...
Page 456: ...Section 8 Operation Figure 118 Real Time Custom 456 ...
Page 457: ...Section 8 Operation 8 8 1 3 Final Memory Tables Figure 119 Final Memory Tables 457 ...
Page 458: ...Section 8 Operation 8 8 2 Run Stop Program Figure 120 Run Stop Program 458 ...
Page 460: ...Section 8 Operation Figure 122 File Edit 460 ...
Page 461: ...Section 8 Operation 8 8 4 PCCard Memory Card Display Figure 123 PCCard CF Card Display 461 ...
Page 478: ......
Page 506: ......
Page 536: ......
Page 636: ......
Page 642: ......
Page 644: ......
Page 676: ......
Page 677: ......