3.69
EDH0162En1040 – 06/99
MM4005
LX — Define X position and build a
line segment = ƒ (LX, tangent)
Usage
IMM
PGM
MIP
Syntax
LXnn
Parameters
Description
nn
[double]
— X coordinate to reach with a line segment.
Range
nn
—
-1.0 E
12
to
1.0 E
12
.
Units
nn
— Preset units in SETUP mode.
Defaults
nn
Missing: Error C.
Out of range: Error C.
Description
This command defines to the controller to build an element of trajectory of
the type: line segment = ƒ (LX, tangent).
Returns
None.
Errors
C
—
Parameter out of limits.
H
—
Calculation overflow.
S
—
Communication time-out.
V
—
Too long trajectory.
Y
—
Trajectory: Line (x, y). Line expected.
[
—
Trajectory: Line (x,
θ
) or Line (y,
θ
) impossible.
e
—
Trajectory: Units not translationnal or not identical.
Rel. Commands
LY
—
Define Y position and build a line segment = ƒ (LY, tangent).
XE
—
Tell the last element.
Example
NT
|
Clear trajectory.
FA45.0
|
Define input tangent = 45°.
LX10
|
Define and build line segment = ƒ (10.0, 45.0°).
XE
|
Tell last element.
XE, Line (x,
θ
), 10, 10, 45
|
Controller tells the built element.