3.133
EDH0162En1040 – 06/99
MM4005
TL — Read left travel limit
Usage
IMM
PGM
MIP
Syntax
xxTL
Parameters
Description
xx
[int]
— Axis number.
Range
xx
—
1
to
4.
Units
xx
— None.
Defaults
xx
Missing: Error B.
Out of range: Error B.
Floating point: Error A.
Description
This command reads the left software travel limit, the motion soft limit in
the negative direction. This is the value set by the SL command or in the
front panel setup menu.
NOTE
The software travel limit values are automatically changed when a home
position is forced at a new location, or if the home preset value is modified.
This is done to maintain the travel limits fixed relative to the physical
location of the limit switches and mechanical stops. By doing so, the
motion device is protected from damage due to a hardware stop.
Returns
xxTLnn
xx
—
Axis number.
nn
—
Negative software travel limit.
Errors
A
—
Unknown message code.
B
—
Incorrect axis number.
S
—
Communication time-out.
Rel. Commands
SL
—
Set left travel limit.
Example
3TL
|
Read left software travel limit on axis #3.
3TL14.5
|
Controller returns left software travel limit 14.5 units.