DO — Read home search velocity
Usage
IMM
PGM
MIP
Syntax
xxDO
Parameters
Description
xx
[int]
— Axis number.
Range
xx
—
1
to
4.
Units
xx
— None.
Defaults
xx
Missing: Error B.
Out of range: Error B.
Floating point: Error A.
Description
This command reads the velocity to be used in the home search cycle. This
is the high velocity of the algorithm, the other ones being scaled down
from it.
The home search high velocity is set by the OH command or from the front
panel SETUP menu.
Returns
xxDOnn
xx
—
Axis number.
nn
—
Home velocity value, in pre-defined units/sec.
Errors
A
—
Unknown message code.
B
—
Incorrect axis number.
S
—
Communication time-out.
Rel. Commands
OH
—
Set home search high velocity.
Example
2DO
|
Read home search high velocity on axis #2.
2DO2.5
|
Controller returns for axis #2 a home search velocity of 2.5.