EDH0162En1040 – 06/99
3.80
MM4005
NB — Set trajectory element
where the generation of pulses starts
Usage
IMM
PGM
MIP
Syntax
NBnn
or
NB?
Parameters
Description
nn
[int]
— Number of trajectory element where the pulses genera-
tion commences.
?
— Read the number of trajectory element where the puls-
es generation starts.
Range
nn
—
1
to
100.
Units
nn
— None.
Defaults
nn
Missing: 1.
Out of range: Error C.
Description
This command sets number of trajectory element where the generation of
pulses commences. The generation of pulses is started immediately in the
beginning of this element.
NOTE
As the total element number of a trajectory may be inferior than 100 and
the value of NB must be
≤
the value of NE
≤
the total element number,
this value of NB will be reexamined in NS and ET commands.
Returns
If the sign
“?”
takes place of the
nn
value, this command reportes the num-
ber of trajectory element where the generation of pulses commences.
Errors
A
—
Unknown message code.
B
—
Incorrect axis number.
C
—
Parameter out of limits.
D
—
Unauthorized execution.
Rel. Commands
NE
—
Set trajectory element where the generation of pulses ends.
NI
—
Set step (curvi-linear distance) between synchronisation pulses.
NN
—
Set number of synchronisation pulses to generate.
Example
NB3
|
Generation of pulses starts at the beginning of the element #3.
NB?
|
Read element number where the generation of pulses starts.
NB3
|
Controller tells the value.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com