Command reference
213455-L, October 2005
/cfg/net/if
<interface number>
Interface Menu
The Interface Menu is used to configure IP interfaces for the firewall. Each IP interface should
be configured to represent a network attached to the firewall.
speed
<port speed>
This command is used to set the link speed of the port. Enter the port speed as an integer
representing Mb/second.
For Fast Ethernet ports, speed can be set to 10 or 100.
For Gigabit Ethernet ports, speed is fixed at 1000.
mode
This command is used to set the port duplex mode to either full-duplex or half-duplex.
The default setting is
full
.
[Interface 1 Menu]
addr1 - Set IP address for host 1
addr2 - Set IP address for host 2
mask - Set Subnet mask
vlanid - Set VLAN tag id
port - Set Port number
vrrp - VRRP Interface Menu
mgmt - Enable management through this interface
ena - Enable interface
dis - Disable interface
del - Remove Interface
Table 55
Port Menu (/cfg/net/port) (Continued)
Command Syntax and Usage