Copyright © Siemens AG 2016. All rights reserved
152
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
GDMA_FINISHED_JOBS
Address:
94h
Bits:
31dt0
Reset value:
00000000h
Attributes: rh w
Description:
Finished Job(31:0) State (write 1 to clear)
(INTR_EN independent)
0 = not finished, 1 = finished
Register:
GDMA_ACTUAL_STATUS
Address:
98h
Bits:
31dt0
Reset value:
0000001Fh
Attributes: r(h)
Description:
Actual Job State
Bit
Identifier
Reset
Attr. Function
/
Description
4dt0 ACT_JOB
1Fh
rh
Actual Job Number – the number of the
running Job
5dt5 ACT_JOB_VAL
0h
rh
Actual Job Number Valid
0 = no job running,
1 = Job Number valid
Note: this flag is needed for ACT_JOB
= “00000”
31dt6 <notused>
0000000h r
all bits
= '0'
Register:
GDMA_IRQ_STATUS
Address:
9Ch
Bits:
31dt0
Reset value:
00000000h
Attributes: rh w
Description:
Job finished, Interrupt generated (INTR_EN dependent) (write 1 to
clear)
0 = Job not finished,
1 = Job finished
Register:
GDMA_ERR_IRQ_STATUS
Address:
A0h
Bits:
31dt0
Reset value:
00000000h
Attributes: r(h) (w)
Description:
Error interrupt State register
Bit
Identifier
Reset
Attr. Function
/
Description
0dt0 ERR_DST_ADDR
0h
rh w
DMA Destination Address Error (write 1
to clear)
0 = no Error, 1 = Error occurred
5dt1 ERR_DST_ADDR_JOB_NR 00h
rh
DMA Destination Address Error JOB
number
6dt6 ERR_AHB
0h
rh w
AHB Master Interface Error (write 1 to
clear)